Peppers防爆格兰(UL-U系列)
Peppers cable gland Type UL-U
代理商:上海颐品自动化科技有限公司
Peppers防爆格兰,Peppers防爆变径,Peppers防爆堵头,Peppers防爆呼吸阀
Peppers cable gland
Double Seal Barrier Gland Designed for use with Unarmoured
Cable featuring Peppers T-1000 Compound
Class I Div 2 : Class II Div 1 : Class III Type 4 X : Ex db : Ex eb
Ex nR : Ex ta : AEx d : AEx e : AEx ta : IP66 : IP68

PRODUCT DEscriptION
“UL-U” type glands, certified Explosion Proof Class I Div 2, Gas Groups ABCD, Flameproof Ex db,
Increased Safety Ex eb, Restricted Breathing Ex nR & Dust Protected Ex ta. They are suitable for use
in Zone 1, Zone 2, Zone 20, Zone 21, Zone 22, Group I Mining, Gas Groups IIA, IIB, IIC and Dust Groups
IIIA, IIIB, IIIC. Occasionally referred to as “potting glands”, they provide a compound barrier Ex db &
IP seal on the cable inner cores, eliminating damage to cables that exhibit “cold flow” characteristics
and an environmental seal on the outer sheath. The gland is suitable for use with all certified Marine
Shipboard Cable and Tray Cable whilst being UL listed for Marine Shipboard Unarmoured, Jacketed
or Non Jacketed cable. A unique feature includes, Peppers T-1000, the sealing compound that
enables a quick and easy installation. The gland is AEx d, AEx e, AEx ta approved and rated Type
4X, maintains IP66, IP68 to 100 metres and is deluge proof without the use of an additional seal or
deluge boot.
COMPLIANCE STANDARDS:
UL514B, UL1203, UL2225, UL50E, ANSI/UL 60079-0/1/7, ISA 60079-31
C22.2 No. 0/25/30/94.1/94.2/174 & CAN/CSA C22.2 60079-0/1/7/31
EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-15, EN 60079-31
IEC 60079-0, IEC 60079-1, 60079-7, IEC 60079-15, IEC 60079-31 & IEC 60529

Example Part Numbering(See below for details)
UL-UB/NP/20/075NPT
Materials: Brass or Stainless Steel

16 M20 x 1.5 1/2” or 3/4” 0.630 0.783 - 0.795 15 1 0.409 0.134 0.331 2.717 1.000 1.102 0.602 EL24
20S M20 x 1.5 1/2” or 3/4” 0.630 0.783 - 0.795 35 4 0.409 0.189 0.461 2.717 1.000 1.102 0.590 EL24
20 M20 x 1.5 1/2” or 3/4” 0.630 0.783 - 0.795 40 8 0.492 0.374 0.551 2.717 1.180 1.299 0.710 EL30
25 M25 x 1.5 3/4” or 1” 0.630 0.795 - 0.985 60 16 0.701 0.461 0.787 2.953 1.480 1.630 1.120 EL38
32 M32 x 1.5 1” or 1 ¼” 0.630 0.985 - 1.008 80 30 0.925 0.713 1.035 3.425 1.810 1.992 1.797 EL46
40 M40 x 1.5 1 ¼” or 1 ½” 0.630 1.008 - 1.024 130 60 1.134 0.890 1.268 3.543 2.170 2.832 2.577 EL55
50S M50 x 1.5 2” 0.630 1.059 200 5 1.346 1.110 1.504 3.937 2.560 2.815 3.770 EL65
50 M50 x 1.5 2” 0.630 1.059 400 5 1.551 1.303 1.736 3.937 2.560 2.815 3.263 EL65
63S M63 x 1.5 2 ½” 0.748 1.571 400 4 1.764 1.547 1.972 3.937 3.150 3.465 6.190 EL80
63 M63 x 1.5 2 ½” 0.748 1.571 425 4 1.969 1.839 2.205 3.937 3.150 3.465 5.309 EL80
75S M75 x 1.5 3” 0.748 1.634 425 4 2.181 2.059 2.441 3.937 3.890 4.280 6.960 EL104
75 M75 x 1.5 3” 0.748 1.634 425 4 2.394 2.283 2.677 3.937 3.890 4.280 6.490 EL104



• Gland size does not necessarily equate to the entry thread size.
• UL approval/applications have a reduced core quantity. Consult product installation instructions for specific core data.
• Dimensions (A) & (B) may differ for glands with non metric entry threads. Please refer to our “Thread Reference Tables” for specific dimensions.
• Assembly instructions must be read prior to installation and adhered to in full.
• Peppers supply cable glands with parallel entry threads that conform to the flameproof threaded joint requirements of IEC/EN 60079-1 and other equivalent standards. They
usually incorporate a thread run out according to the available machining techniques and will not have a full form thread for the entire length. Peppers Cable Glands Limited will
not be held responsible for clients’ installations where this has not been taken into account.
• When selecting IP Washer & Shroud material for use with glands, please be aware of the accessories temperature range to ensure they are suitable for the intended installation.
• The gland is supplied with the correct amount of the two-part compound, gloves and instructions to allow one complete termination.
• All brass entry threads are Nickel Plated as standard.
• Where approval in addition to UL, CSA, ATEX, and IECEx is required, this must be clearly requested at time of enquiry / order.



Peppers防爆格兰,Peppers防爆变径,Peppers防爆堵头,Peppers防爆呼吸阀
Hawke防爆格兰,Hawke
防爆变径,Hawke防爆堵头,Hawke防爆呼吸阀等
Feam防爆格兰,Bartec防爆变径,Feam防爆堵头,Bartec防爆呼吸阀等
Cooper防爆格兰,Cooper爆变径,Cooper防爆堵头,Cooper防爆呼吸阀等
CCG防爆格兰,CCG防爆变径,CCG防爆堵头,CCG防爆呼吸阀等
CMP防爆格兰,CMP防爆变径,CMP防爆堵头,CMP防爆呼吸阀等
Peppers防爆格兰及附件代理商:上海颐品自动化科技有限公司





询价单
0条  相关评论